P B M  CHARGERS - Fine Battery Chargers from Italy

Power Point - Single Phase
Charging Time 10-12 Hours

• Single-phase input voltage:208/240/480V AC – Frequency: 50/60 Hz.
• Transformer adjustments to
±5%V AC.
• Tropicalized stray-flux transformer, copper windings with double enamel
   insulation, class H, impregnated with non-toxic resins, kiln-dried.
• Transformer with
UL recognized insulation system which ensures high
   reliability even in difficult operating conditions.
• Low voltage control circuit (24V AC).
• Overload cutout on transformer.
• Rectifier bridge equipped with interference suppressing filters.
• Protection fuses on mains input, and D.C. output.
• Final acceptance test conforming to safety regulations.
• Complete with charging cables and connector.
•
Power cord to be installed by the customer.

• Electronic controller AP735USA with microprocessor and failure diagnostics
   powered from battery voltage.
• Polycarbonate plate with LED’s indicating the charging stages or faults, if any
• Lab-tested electronic circuit conforming to the EMC-Directive and CE marking.
• Charger switching off on battery disconnection while on charge.
• Short check of functions and times.
• 4 digit LCD with 12 multifunctional symbols

Power Point - Three Phase
Charging Time 10-12 Hours

• Three-phase input voltage: 208/240/480/600V AC – Frequency: 50/60 Hz.
• Transformer adjustments to
±5%V AC.
• Tropicalized stray-flux transformer, copper windings with double enamel
   insulation, class H, impregnated with non-toxic resins, kiln-dried.
• Transformer with
UL recognized insulation system which ensures high
   reliability even in difficult operating conditions.
• Low voltage control circuit (24V AC).
• Overload cutout on transformer.
• Rectifier bridge equipped with interference suppressing filters.
• Protection fuses on mains input, and D.C. output.
• Final acceptance test conforming to safety regulations.
• Complete with charging cables and connector.
•
Power cord to be installed by the customer.

• Electronic controller AP735USA with microprocessor and failure diagnostics
   powered from battery voltage.
• Polycarbonate plate with LED’s indicating the charging stages or faults, if any
• Lab-tested electronic circuit conforming to the EMC-Directive and CE marking.
• Charger switching off on battery disconnection while on charge.
• Short check of functions and times.
• 4 digit LCD with 12 multifunctional symbols

Power Point - Three Phase
Charging Time 7 - 8 Hours
Three Shift Charger

• Three-phase input voltage: 208/240/480/600V AC – Frequency: 50/60 Hz.
• Transformer adjustments to
±5%V AC.
• Tropicalized stray-flux transformer, copper windings with double enamel
   insulation, class H, impregnated with non-toxic resins, kiln-dried.
• Transformer with
UL recognized insulation system which ensures high
   reliability even in difficult operating conditions.
• Low voltage control circuit (24V AC).
• Overload cutout on transformer.
• Rectifier bridge equipped with interference suppressing filters.
• Protection fuses on mains input, and D.C. output.
• Final acceptance test conforming to safety regulations.
• Complete with charging cables and connector.
•
Power cord to be installed by the customer.

• Electronic controller AP735USA with microprocessor and failure diagnostics
   powered from battery voltage.
• Polycarbonate plate with LED’s indicating the charging stages or faults, if any
• Lab-tested electronic circuit conforming to the EMC-Directive and CE marking.
• Charger switching off on battery disconnection while on charge.
• Short check of functions and times.
• 4 digit LCD with 12 multifunctional symbols

Heavy Duty
Battery Charger

TL EQUALIZER UL


Charging Time 9-12 Hours

 

Simple and robust battery charger suitable for charging monoblocks and lead acid traction batteries. Suitable for floor washers and electric pallet trucks. Available with WA charging profile for
9 -12h recharge, 110 / 208 / 240VAC single phase. It is a reliable and simple product in use.

POKER UL

Advanced multi-cell Ferro charger excels in battery shop, rental and loaner-type installations.
For battery from 12V to 48V. 
Equipped with AC cable cord and DC cable output.

Copyright Lighthouse Enterprises 1998-2024  Privacy Policy   About Us  Contact Us  Shipping and Returns
  Prices are subject to change without notice due to errors on our part or price increases!
www.CentralVacuumMotor.com, www.CartPartsRUS.com, www.BatteryChargerDepot.com
 www.FloorScrubberPartsDepot.com, www.FloorSweeperPartsDepot.com, www.lighthouseenterprises.us